Wall Mounted Split
Product Description: Electromagnetic flowmeters are suitable for measuring almost all electrically conductive liquids, a
Send your inquiryDESCRIPTION
Basic Info.
Model NO. | MD-EL-F |
Application | Industrial Production |
Type | Electromagnetic Flow Meter |
Measuring Media | Liquid |
Measuring Principle | Electrical Principles |
Measurement Object | Closed Pipeline |
Certification | ISO |
Power | 24VDC |
Transport Package | Carton |
Specification | >5 |
Trademark | Meokon |
Origin | Shanghai |
Production Capacity | 50000 PCS/Year |
Product Description
Product Description:
Electromagnetic flowmeters are suitable for measuring almost all electrically conductive liquids, as well as mud, paste and mud flow measurements. This is provided that the medium under test has at least a certain minimum conductivity. Temperature, pressure, viscosity and density have no effect on the measurement results.It can also be used to measure corrosive media with the appropriate choice of pipe lining and electrode materials. Solid particles in the medium will not affect the measurement results. The flow sensor and the intelligent converter form a complete flowmeter in whole or separately. The product application
Application:
Clean water &sewage
Electricity production &distribution
Chemical & industrial pharmacy
Food industry
Technical characteristics:
1. No moving parts and no wear
2. The measurement range of the process is 1: 100
3. No clear section or flow enhancement device
4. Measuring the flow rate of various conductive liquids
5. Measurement results are not affected by physical properties such as temperature, pressure, viscosity, and density
6. Strong corrosion resistance and wear resistance
7. Measures forward / reverse flow
8. Large LCD screen, user-friendly operation interface, easy to use
9. Persistent EEPROM for saving configuration parameters and measurement data during power failure
10. Wide operation voltage range
11. Self-diagnosis
Specification:
Display | LCD display, display various flow data in real-time, m³ or L display unit | ||
Structure | Embedded type design, integrated or split type | ||
Measuring medium | Liquid or solid-liquid, Conductivity> 0.5μs / cm2 | ||
Measuring Range | 0.05m/s~8m/s | ||
Measurement Accuracy | Diameter mm | Range m/s | Accuracy |
3~20 | 0.3 or less | ±0.25%FS | |
0.3~1 | ±1.0%R | ||
1~10 | ±0.5%R | ||
25~600 | 0.1~0.3 | ±0.25%FS | |
0.3~1 | ±0.5%R | ||
1~10 | ±0.3%R | ||
700~3000 | 0.3 or less | ±0.25%FS | |
0.3~1 | ±1.0%R | ||
1~10 | ±0.5%R | ||
%FS: relative range, %R: relative measurement | |||
Caliber(mm) | 6mm~2000mm | ||
Nominal pressure | PN6, PN10, PN16, PN25, PN40, PN63, PN100, PN160, PN250, PN420 etc. | ||
Output | 4~20mA or frequency (<5KHz), RS485, wireless transmission (optional), relay (option al) | ||
Connection | DN6 ~ DN2000 for flange connection | ||
Connection standard | Applicable to various pipe flange standards | ||
Product Standards | Accuracy requirements meet JJG 1033-2007 standard | ||
IP rating | IP65(integrated), IP67 or IP68 when split (optional) | ||
Power supply | AC86~220V | ||
Ambient temperature | 5~55ºC | ||
Environment humidity | <85%r.h(Non-condensing) |