Electronic Water Flow Meter, Electromagnetic Flowmeters, Magnetic Flowmeters

Products

Electronic Water Flow Meter, Electromagnetic Flowmeters, Magnetic Flowmeters

Electronic Water Flow Meter, Electromagnetic Flowmeters, Magnetic Flowmeters

E8000 Series Electromagnetic flometer Converters One-piece Intelligent electromagnetic circuit board 1, Various output i

Send your inquiry

DESCRIPTION

Basic Info.
Model NO. E8000
Certification Pcec
Relative Humidity 5%~90%
Output 4-20mA
Warranty 1 Year
Power Supply 220VAC + Hart
Turndown Ratio 150:1
Color Black
Transport Package Paper Carton and as Buyer′s Requirement
Specification About 2kg
Trademark BJZRZC
Origin Beijing China
HS Code 902690000
Production Capacity 10000 PCS / Month
Product Description

E8000 Series Electromagnetic flometer Converters

One-piece Intelligent electromagnetic circuit board

1, Various output interfaces are available: 4-20mA / 0-10mA / Pulse or Frequency output / RS232 or RS485-MODUSBUS interfaces.

2, Dot matrix LCD 128*64, Chinese / English support.

3, High-brightness(emerald) backlight for dark environment.

4, Modular design, ensuring high reliability, consistency, and longer stability.

5, Product model series:

E8000AR: 220VAC, RS485-MODBUS RTU,

4-20mA , 0-10 mA , Pulse/Frequency

E8000DR: 24VDC, RS485-MODBUS RTU, 4-20mA , 0-10 mA , Pulse/Frequency

One-piece Intelligent electromagnetic circuit board

1, Various output interfaces are available: 4-20mA / Pulse Equipment or Frequency output ,HART.

2, Dot matrix LCD 128*64, Chinese / English support.

3, High-brightness(emerald) backlight for dark environment.

4, Modular design, ensuring high reliability, consistency, and longer stability.

5, Product model series:

E8000AH: 220VAC , HART, 4-20mA

Pulse Equipment Output /Frequency Output

E8000DH: 24VDC, HART, 4-20mA ,

Pulse Equipment Output /Frequency Output

Split type Intelligent electromagnetic circuit board

1, Various output interfaces are available: 4-20mA / 0-10mA / Pulse or Frequency output , RS232 or RS485-MODUSBUS interfaces.

2, Dot matrix LCD 128*64, Chinese / English support.

3, High-brightness(emerald) backlight for dark environment.

4, Modular design, ensuring high reliability, consistency, and longer stability.

5, Product model series:

E8000F-AR: 220VAC, RS485-MODBUS RTU,

4-20mA , 0-10 mA , Pulse/Frequency

E8000F-DR: 24VDC, RS485-MODBUS RTU,

4-20mA , 0-10 mA , Pulse/Frequency

Split type Intelligent electromagnetic circuit board

1, Various output interfaces are available: 4-20mA / Pulse Equipment / Frequency output , HART.

2, Dot matrix LCD 128*64, Chinese / English support.

3, High-brightness(emerald) backlight for dark environment.

4, Modular design, ensuring high reliability, consistency, and longer stability.

5, Product model series:

E8000F-AH: 220VAC , HART, 4-20mA

Pulse Equipment Output /Frequency Output

E8000F-DH: 24VDC, HART, 4-20mA ,

Pulse Equipment Output /Frequency Output


The basic function of keys as follow:

FEATURES

1, Intelligent Excitation: Sensor resistance ranges from 30 to 110 ohms. The excitation voltage can be automatically adjusted according to the impedance, which can reduce heat of the circuit board and the temperature drift.

2, Real-time drift control technology: Eliminate automatically the potential drift of measuring electrode and the amplifier circuit drift.

3, Turndown ratio 150:1

4, Multiple variables can be displayed simultaneously: instantaneous flow, total flow, flow rate, positive flow, negative flow, and the alarm state.

5, Chinese / English support.

6, Data backup and restore.

7, Various alarm functions: support excitation, pipes empty, upper and lower alarm.

8, Small flow linear correction functions: Support small flow four-point linear correction.

9, Converters and sensors coefficients can be set independently. Converter interchangeable.

10, Various output interfaces are available:

Analog output: 4 ~ 20mA or 0 ~ 10mA current loop output

Pulse or frequency output

Switch alarm output

11, RS485 communication, or HART communication option

12, Modular design, ensuring high reliability, consistency, and long-term stability. Measurement State DisplayElectromagetic Flowmeter

Measure precision for assembly:

Diameter(mm)

Range(m/s)

Accuracy

3 ~ 20

< 0.3

±0.25%FS

0.3~1

±1.0R

1~15

±0.5%R

25 ~600

0.1~0.3

±0.25%FS

0.3~1

±0.5%R

1~15

±0.3%R

700~3000

< 0.3

±0.25%FS

0.3~1

±1.0%R

1~15

±0.5%R

%FS:for relative ranges;

%R:for relative value of measurement

E8000 Wiring Terminal
E8000 Symbols and description of connectors:

IOUT-:4~20mA/0~10mA Output Current Ground
IOUT+:4~20mA/0~10mA Output Current Positive
PCOM:Frequency (Pulse) Output Ground/Upper And Lower Alarm Ground
P/AH:Frequency (Pulse) Output Ground /Upper Alarm Output
AL:Alarm Output for Low Limit / Flow Direction Output
TX-:Communication Input Signal, RS485 B
TX+:Communication Input Signal, RS485 A
L:(+)220V Power Supply L.(24V Power Supply +)
N:(-)220V Power Supply N.(24V Power Supply -)

E8000F Sub-body Type Wiring Terminal:

Electronic Water Flow Meter, Electromagnetic Flowmeters, Magnetic Flowmeters

Flow rate flow(m³/h) (m/s) caliber(mm)0.111015
DN100.02827 0.282742.827434.24114
DN150.06362 0.636176.361719.54257
DN200.11310 1.1309711.309716.9645
DN250.17671 1.7671417.671426.5071
DN320.28953 2.8952828.952843.4293
DN400.45239 4.5238845.238867.8583
DN500.70686 7.0685770.6857106.028
DN651.19459 11.9458119.458179.188
DN801.80956 18.0955180.955271.433
DN1002.82743 28.2743282.743424.114
DN1254.41786 44.1786441.786662.679
DN1506.36172 63.6171636.171954.257
DN20011.3097113.0971130.971696.45
DN25017.6714 176.7141767.142650.71
DN30025.4468254.4682544.683817.03
DN600101.7871017.8710178.715268.1
DN1000282.743 2827.4328274.342411.5
DN20001130.9711309.7113097169645
DN30002544.6925446.9254468381703